VI - POWER PLUS MODE
ARC DETECT IS DISABLED! Use CAUTION
This is an active mode used for activating electrical components similar to PPHM except the Arc Detect feature is dis-
abled. The Power Switch and Circuit Breaker Preferences apply here in Power Plus Mode as they do in PPHM. Power
Plus Mode will measure and display the Min/Max Current draw so you capture in rush and stabilized current. High current
can be an indication of a sticking or dragging motor or pump.
To access Power Plus Mode from PPHM:
1. Press SEL once.
2. Press U once
3. Press SEL.
4. You should see AMP in the display.
To activate an electrical component in Power Plus Mode:
1. If the electrical component is already grounded in the
vehicle, you can skip step 2.
2. Connect the auxiliary ground lead to the ground of the
electrical component.
3. Contact the probe tip to the positive terminal of the
component.
4. Press (+). The component should activate.
5. Read the display for the average current draw along with
the Min/Max measurements.
6. To reset the Min/Max Press R
VII - VOLT METER MODE
The Volt Meter Mode is a passive mode. The (+) Power and (–)
Power buttons are not active so dynamic circuit testing cannot
be performed. This means, no Power will be activated to the
probe tip even when you press the Power buttons.
Volt Meter Mode monitors the probe tip and displays 3 voltage
measurements, Average, Min. and Max.
Min/Max can be reset by pressing the R button.
To access Volt Meter Mode from PPHM:
1. Press SEL once.
2. Press D, 4 times.
3. Press SEL once.
4. Connect the probe tip to the circuit you want to
monitor and test.
5. Press R to reset the Min/Max
OT
V
L
0
0
0
OT
V
L
21
6
21
6
21
6
OT
V
L
21
6
0
21
6
Now reset by pressing
the RIGHT ARROW
button. Min is now the
same as Max.
When you touch the tip
to the positive battery
post the average reading
and the max will read the
same. The Min will re-
main 0 since it recorded
the previous low.
M
A
P
0
0
00
0
0
Vue de la page 9